Active RCDs

Usually used with power tools or electrical equipment where unexpected restarting could present a danger to the user in a power cut situation.
Active devices need to be manually reset after each activation. 

Available as Switched Sockets, Fused Spur Units, Inline, Plug & Adaptors.

Switched 30mA Socket

Tech Data

Voltage: 230V AC 50Hz
Max operating current: 13A (13A inductive)
Rated trip current: 30mA
Typical trip speed: Less than 20mS (typical)
RCD contact break: Double pole
Latching: Electrical - manual reset
Responsive to: Pulsating DC earth faults
Conforms to: BS 7288:1990, Amd 1 and BS 1363-2:1995 Amd 1-3
EMC Emissions: EN 55014-1:2006 & EN55014-1:2000 inc A1:2001 & A2:2002
EMC Immunity: EN 61543:1995 inc A11:2003, A12:2005 & A2:2006

Switched 10mA Socket

Conforms to: BS 7288:1990, Amd 1 and BS 1363-2:1995 Amd 1-3
EMC Emissions: EN 55014-1:2006 & EN55014-1:2000 inc A1:2001 & A2:2002
EMC Immunity: EN 61543:1995 inc A11:2003, A12:2005 & A2:2006

Tech Data

Voltage: 230V AC 50Hz
Max operating current: 13A (13A inductive)
Rated trip current: 10mA
Typical trip speed: Less than 20mS (typical)
RCD contact break: Double pole
Latching: Electrical - manual reset
Responsive to: Pulsating DC earth faults

30mA Fused Spur

Tech Data

Voltage: 230V AC 50Hz
Max operating current: 13A (13A inductive)
Rated trip current: 30mA
Typical trip speed: Less than 20mS (typical)
RCD contact break: Double pole
Latching: Electrical - manual reset
Responsive to: Pulsating DC earth faults
Conforms to: BS 7288:1990, Amd 1 and BS 1363-2:1995 Amd 1-3
EMC Emissions: EN 55014-1:2006 & EN55014-1:2000 inc A1:2001 & A2:2002
EMC Immunity: EN 61543:1995 inc A11:2003, A12:2005 & A2:2006

10mA Fused Spur

Conforms to: BS 7288:1990, Amd 1 and BS 1363-2:1995 Amd 1-3
EMC Emissions: EN 55014-1:2006 & EN55014-1:2000 inc A1:2001 & A2:2002
EMC Immunity: EN 61543:1995 inc A11:2003, A12:2005 & A2:2006

Tech Data

Voltage: 230V AC 50Hz
Max operating current: 13A (13A inductive)
Rated trip current: 10mA
Typical trip speed: Less than 20mS (typical)
RCD contact break: Double pole
Latching: Electrical - manual reset
Responsive to: Pulsating DC earth faults

Inline RCDs

Tech Data

Voltage: J62-T 230V AC 50Hz/J62-Y 110V AC 50Hz
Max operating current: 16A (13A inductive)
Rated trip current: 30mA
Typical trip speed: Less than 20mS (typical)
RCD contact break: Double pole
Latching: Electrical - manual reset
Responsive to: Pulsating DC earth faults

RCD Plug and Adaptor 

Tech Data

Voltage: 230V AC 50Hz
Max operating current: 13A (13A inductive)
Rated trip current: 30mA
Typical trip speed: Less than 20mS (typical)
RCD contact break: Double pole
Latching: Electrical - manual reset
Responsive to: Pulsating DC earth faults